OMD-2005 Bilge water alarm
OMD- 2005 15 ppm Bilge Alarm according to IMO Resolution MEPC.107 (49)

Specification
|
Range (measurement & indication)
|
0 - 30 ppm, Trend up to 50ppm
|
|
Range (IMO specification)
|
0 - 15 ppm (according IMO regulations)
|
|
Accuracy
|
better than IMO MEPC.107(49)
|
|
Electrical power supply
|
24V - 240V, AC or DC, automatic voltage adjustment
|
|
Electrical power consumption
|
< 15 VA
|
|
Sample
|
Oily water from separator outlet, 0,1 - 4 l/min
|
|
Sample temperature range
|
+1°C to +65°C
|
|
Sample connections
|
R 1/4" Female
|
|
Alarm 1 & 2 Set Points
|
1 - 15ppm (independently adjustable)
|
|
Alarm 1 operating delay for annunciation
|
1 - 540 sec
|
|
Alarm 2 operating delay for control
|
1 - 10 sec
|
|
Alarm contacts
|
2 independently adjustable switchover contacts
|
|
Alarm contact operation mode
|
De-energized in Alarm State
|
|
Alarm contact ratings
|
3A, 240V each
|
|
Alarm output
|
0 - 20 mA or 4 - 20 mA, for 0-30ppm reversible, ext. Load<150
|
|
Display
|
Green Graphic Display
|
|
Ambient temperature
|
+1°C to +55°C
|
|
Class of protection
|
IP 65
|
|
Dimensions
|
360 x 240 x 100 mm (WxHxD)
|
|
Weight
|
7,3 kgs
|